arrow_back Retour aux freelances
F

PGV100 Sensor-Kinco PLC Integration

Freelancer

Partager:
placeIN home_workTélétravail assignmentCDD publicOffre agrégée · IN

eventPubliée le 29 sept. 2026 · verifiedNous avons confirmé le 02 oct. 2026 qu'elle est toujours active

Cette entreprise est la vôtre ?

₹ 600 – ₹ 1.500 par projet

À propos de l'offre

### P&F PGV100-F200-R4-V19 Integration with Kinco K615S-16DT PLC I am looking for an experienced **PLC/Industrial Automation programmer** to integrate a **Pepperl+Fuchs PGV100-F200-R4-V19** positioning/color sensor with a **Kinco K615S-16DT PLC**. The sensor communicates through **RS485**, and I need to establish communication between the sensor and PLC and correctly decode the data received from the sensor. ### Main Requirement The PLC should receive and process the data from the **Pepperl+Fuchs PGV100-F200-R4-V19** sensor, including: * Detected **color/code** * Position information * Position/orientation value * Determine whether the detected position is: * **Left** * **Center** * **Right** * Receive and store the corresponding sensor values in PLC registers * Display/use these values in the PLC logic for further machine operation ### Scope of Work The freelancer will need to: 1. Configure the **RS485 communication** between the PGV100 sensor and Kinco K615S-16DT PLC. 2. Understand and implement the communication protocol/data format of the PGV100-F200-R4-V19. 3. Develop the required communication logic in the **Kinco PLC**. 4. Read the sensor's transmitted data into PLC registers. 5. Decode the received data and identify the detected **color/code**. 6. Process the position data and determine **Left / Center / Right** orientation. 7. Create proper PLC register/data mapping. 8. Provide a working PLC program that can be tested directly with the sensor. 9. Troubleshoot communication, data conversion, and decoding issues during commissioning. ### Expected PLC Data I would like the PLC program to provide clearly mapped values such as: | Data | PLC Output | | -------------------- | ------------------------ | | Sensor Communication | Communication OK / Error | | Detected Color | Color/Code value | | Position X | Numeric position value | | Position Status | Left / Center / Right | | Sensor Data | Raw/decoded value | | Sensor Error | Error/status code | The exact data structure will be finalized based on the **PGV100 sensor communication protocol/manual**. ### Hardware **Sensor:** Pepperl+Fuchs PGV100-F200-R4-V19 **Communication:** RS485 **PLC:** Kinco K615S-16DT ### Required Experience Please apply only if you have practical experience with: * Kinco PLC programming * RS485 communication * Modbus RTU / serial communication * Pepperl+Fuchs sensors * Industrial positioning or color sensors * PLC register/data decoding * Industrial automation commissioning ### Deliverables * Complete Kinco PLC program * RS485 communication configuration * PGV100 sensor data decoding * PLC register mapping * Color/code detection logic * Left/Center/Right position logic * Communication error handling * Basic documentation explaining the PLC registers and logic * Remote testing/debugging support I can provide the **PGV100-F200-R4-V19 datasheet/manual and the Kinco PLC programming software/project details** to the selected freelancer. **Please include examples of your previous RS485 sensor-to-PLC integration projects when submitting your proposal.**

Continuez à lire gratuitement

Créez un compte gratuit pour voir l'offre complète et postuler.

  • badgePortfolio visible par les entreprises
  • notificationsAlerte de nouvelle offre par e-mail
  • favoriteToujours gratuit, sans piège