Pubblicata il 23 nov 2026 · Abbiamo verificato il 23 nov 2026 che è ancora attiva
Questa azienda è tua?US$ 250 – US$ 750 per progetto
MANDATORY REQUIREMENT — READ BEFORE BIDDING: You MUST hold an active State of Alabama Registered Architect License (verifiable on the Alabama Board for Registration of Architects) and be willing to apply your official Alabama architectural seal to the final drawings. Do NOT bid if you are only an unlicensed CAD drafter or only hold a PE/engineering license—Alabama law requires a Registered Architect's seal for a Group A-3 Change of Occupancy. Project Overview: We are seeking a flat-fee, fast-turnaround quote to CAD-draft and digitally stamp a minimal, code-compliant 2-sheet Life Safety & Site Compliance package for an existing commercial building in Hamilton, Alabama (Marion County) undergoing a Change of Occupancy to Group A-3 (Recreation / Community Assembly) under the IEBC. What We Are Providing You: Measured interior floor plan layout (PDF/JPG) with exact room dimensions, door widths, and occupancy counts. Aerial site & parking layout plan (PDF/JPG) with exact fire lane widths, ADA parking pad dimensions, and overflow parking layout. Interior and exterior drone/site photos upon award. Exact Deliverables (Strictly Code-Minimum — 2 Sheets Only): Sheet 1 — Interior Life Safety, Egress & Code Summary Plan: Existing 60' x 150' (9,000 sq. ft.) single-story pre-engineered metal building. Total Occupancy Capped at 299 Max (staying 1 person below the 300-person / 12,000 sq. ft. automatic fire sprinkler and fire alarm threshold): Multi-Purpose Floor 1 (57 max), Multi-Purpose Floor 2 (176 max), Game Room (32 max), 3 Private Rental Rooms (8 max each = 24), and Lobby (10 max). Back-of-house/staff-only rooms (Concessions, Storage, Merchandise Room, Office) excluded from assembly counts. Egress & Fire Protection: 1 front 72" double exit + two 36" side exits (all outward-swinging with panic hardware and close-out springs), illuminated EXIT signs, emergency lighting, and 2A-10BC fire extinguishers within 75-ft travel paths. Restrooms: 2 existing single-user unisex restrooms clustered side-by-side (1 outfitted as Unisex ADA-compliant + 1 standard unisex under ADA Section 213.2 Exception 4), supplemented by 2 exterior portable restrooms + handwashing station for peak event fixture counts. Sheet 2 — Exterior Site & ADA Parking Compliance Plan: One-way 20-ft clear fire lane loop (IFC 503.2.1). Concrete ADA parking pad (4 spaces including van-accessible aisle) on the front-left of the lobby entrance. Pinned railroad-tie wheel stops along the west grass slope edge and unimproved natural-grade event overflow parking. Scope Boundaries & Terms: Quote a single flat fee covering CAD drafting from our measured drawings, your State of Alabama Registered Architect digital stamp, and 1 round of minor redline revisions if requested by the local building official/fire marshal. Strictly code-minimum Life Safety & Site sheets only—do not include MEP, structural engineering, or non-required architectural upgrades. In your bid, please state: (1) Your Alabama Architect License number, (2) Confirmation that stamping is included in your flat bid, and (3) Your estimated turnaround time.
Crea un account gratuito per vedere l'offerta completa e candidarti.