Published on Nov 11, 2026 · We confirmed on Nov 11, 2026 that it's still live
Is this your business?US$ 10 – US$ 165 per project
I HAVE ATTACHED AN EXAMPLE IN THE IMAGES OF ALL THAT NEEDS TO BE DONE AND THE REVIT FILE WITH ALL THE CDS Requirements: You will be providing a lighting layout and the necessary documentation for a lighting installation for a commercial space. For the provided plan you will layout the reception area, conference room, office, and corridor leading to the back area. You do not need to layout the open office area unless you would like to. You may make slight modifications to the plan if you feel it will enhance the design and layout of the space, but your focus is the lighting. Your final design should include interesting ceiling design as well as different facets to the lighting (ambient, task, focal, etc.) Apply what you have learned about layered lighting including natural light and control systems. You must use both dropped acoustical ceiling and drywall) (Note: You want your design to have several options for section details, so it is important to provide transitions between materials and heights that incorporate lighting. Think about soffits, valances, backlighting, grazing, etc.) You need to provide the following on your RCP. • Luminaire layout • Switching & Switching loops • HVAC Supply and Return • Sprinkler locations • Emergency Lighting • Exit lights/signs • Sensors (daylight, occupancy) • Smoke/heat, AV alarm systems, CO2 monitors • Ceiling Heights • Ceiling materials (this is a commercial space, most of the ceiling should be some sort of acoustical ceiling product) Be sure to include soffits, coves, or interesting design features for your detail drawings. • Should include dimensioning for all fixtures not in grid ceiling. • Annotation Deliverables: The following items will be turned in and presented on the due date: You will create 2 pdf files: 1. A mini set of construction documents with focus on the lighting. These should be set up as sheets with title blocks. 2. Specifications for the luminaires and ceiling systems used in the design. You will gather the technical specifications from the manufacturers and provide a cover sheet for each. The documents will include: • Lighting Design Concept Statement (be sure to discuss the aesthetics, function, energy efficiency of the design intent) • Floor/Furniture Plan • Electrical on Floor plan (Add outlets, thermostats, telephone, data, switches, etc. on the furniture plan). Provide legend for symbols used. • Annotation on floor plan regarding natural and manmade light • Reflected Ceiling Plan – will include the following: • Ceiling materials • Luminaire Layout • HVAC placement • Sprinkler placement • Emergency exit signs and emergency lighting • Switching & switching loops/Zone Plan • Lighting Schedule (This must include the total wattage per square foot) • Appropriate Legends • Appropriate annotation • Specification Sheets for the Luminaires, exit signs, emergency lighting, and ceiling systems you are recommending (these will be tagged to coordinate with the lighting schedule) You should have a cover sheet for each luminaire you specify to use in the space that includes: • Manufacturer • Product name and # • Technical information ▪ Kelvin scale ▪ CRI ▪ Wattage ▪ Lumen output ▪ Etc. • Finish information • Two Sections of any ceiling detail you would like (1” or 1-1/2” scale) • Illuminance Rendering study (Revit, View, Render in Cloud, select illuminance) You can also use Enscape to do illuminance renderings. You can use the settings to run with daylight and without. Include a written analysis of what you observe with the illuminance renderings. • Calculations on the foot candles for the office and conference room
Create a free account to see the full job and apply.